background image

3-47

IM 04L41B01-62EN

1

2

3

4

5

Index

Detailed Information for

Attributes of Screens and Components

3.23 Attributes of Modbus In Component

(Can only be set with a Version 4.01 screen and a Version 4.11 screen)

The displayed width of the component frame is 1 dot for the DX1000 and 2 dots for the
DX2000.
The following restrictions apply to the attribute settings of Modbus In components.
• [Visible] can only be set when [Depend ID] is set to [None].
• [Maximum] and [Minimum] are not interchangeable.
• If a value smaller than [Minimum] is input for [Maximum], [Minimum] becomes that

value.

• If a value larger than [Maximum] is input for [Minimum], [Maximum] becomes that

value.

List of Settings

Refer to Section 3.3 for attributes without explanations in the list of settings.

Attribute

Set value/choice
(Underlined items are initial

set values)

Description, conditions

X

DX1000: 0 to 318
DX2000: 0 to 638

This is the X-coordinate of the left side of the component.
X = 0 for X < 0
X = (Max.

width

*1

– Width) for (X + Width) > Max. width

*1

Y

DX1000: 24(0) to 238
DX2000: 40(0) to 478
( ) = Status area set to No

display

This is the Y-coordinate of the upper side of the component.
Y = Min. Y

*2

for Y < Min. Y

*2

Y = (Min. Y

*2

+ Max. height

*3

– Height) for (Y + Height) > (Min. Y

*2

+

Max. height

*3

)

*1

DX1000 max. width = 320, DX2000 max. width = 640

*2

DX1000 min. Y = 24(0), DX2000 min. Y = 40(0), ( ) = Status area set to No display

*3

DX1000 max. height = 216(240), DX2000 max. height = 440(80), ( ) = Status area set to No display