beautypg.com

Index – Yokogawa Button Operated DX2000 User Manual

Page 122

background image

3-61

IM 04L41B01-62EN

1

2

3

4

5

Index

Detailed Information for

Attributes of Screens and Components

List of Settings

Refer to Section 3.3 for attributes without explanations in the list of settings.

Attribute

Set value/choice
(Underlined items are initial

set values)

Description, conditions

X

DX1000: 0 to 318
DX2000: 0 to 638

This is the X-coordinate of the left side of the component.
X = 0 for X < 0
X = (Max.

width

*1

– Width) for (X + Width) > Max. width

*1

Y

DX1000: 24(0) to 238
DX2000: 40(0) to 478
( ) = Status area set to No

display

This is the Y-coordinate of the upper side of the component.
Y = Min. Y

*2

for Y < Min. Y

*2

Y = (Min. Y

*2

+ Max. height

*3

– Height) for (Y + Height) > (Min. Y

*2

+

Max. height

*3

)

Width

DX1000: 2 to 320
DX2000: 2 to 640

This is the component width.
Width = 2 for width < 2
X = (Max. width*

1

– Width) for width < Max. width

*1

and (X + Width) >

Max. width

*1

Width = Max. width

*1

, X = 0 for width ≥ Max. width

*1

Height

DX1000: 2 to 216(240)
DX2000: 2 to 440(480)
( ) = Status area set to No

display

This is the component height.
Height = 2 for height < 2
Y = (Max. height*

3

– Height) for height < Max. height

*3

and (Y +

Height) > Max. height

*3

Height = Max. height

*3

, Y = 0 for height ≥ Max. height

*3

Batch group number

Setting range: 1 to multi-

batch number set by the

basic settings of the DX

recorder
DX1000: [1] to [6]
DX2000 standard memory:

[1] to [6]

DX2000 expanded memory:

[1] to [12]

This is the batch group number which can be selected within the

range of the multi-batch number set by the basic settings of the DX

recorder.
This item cannot be set when multi-batch of the DX recorder is OFF.

Display Grp no

when multi-batch is Off.
DX1000: [1] to [10]
DX2000: [1] to [36]
when multi-batch is On.
DX1000: [1] to [6]
DX2000: [1] to [12]

This is the batch group number that can be selected within the range

of the number of multibatches set in the basic settings on the DX

recorder.
The group selection range differs according to the batch.

Kind

[Off], [On], [Bmp]

This is the scale plate kind.
Off: A simple scale plate without scale values
On: Display with the scale plate display divided into the set number of

divisions and drawing of scale values at fixed intervals.

Bitmap: A bitmap designed by the user is used for the scale plate.

Bitmap filename

Input is possible for max. 51

single-byte alphanumeric

characters.

This specifies the file name of the bitmap to be displayed.
This is effective when “Kind” is [Bmp]. This is the name of the bitmap

file to be pasted onto the scale plate.
The bitmap file read destination is the folder that the latest display

data (.CDC) has saved.

Form

[Small], [Large]

Scale band format. When the format is [Small] and the channel’s

green band setting is [Off] in the settings file, the area for the scale

value and units is filled with the background color of the scale band.
If there is no settings file, the channel’s green band setting is Off.
Small: A small scale plate

The same image as for 4-screen display with DX2000 or the

scale plate with DX1000.

Large: A large scale plate

This is the same image as for the scale plate at the time of

other than 4-screen display with DX2000.

*1

DX1000 max. width = 320, DX2000 max. width = 640

*2

DX1000 min. Y = 24(0), DX2000 min. Y = 40(0), ( ) = Status area set to No display

*3

DX1000 max. height = 216(240), DX2000 max. height = 440(80), ( ) = Status area set to No display

3.29 Attributes of Scale Components

This manual is related to the following products: