19 attributes of label components, 19 attributes of label components -39, Index – Yokogawa Button Operated DX2000 User Manual
Page 100
3-39
IM 04L41B01-62EN
1
2
3
4
5
Index
Detailed Information for
Attributes of Screens and Components
3.19 Attributes of Label Components
You can double-click a component to directly input a text label on the component. After
input, press the Return key or click the mouse anywhere outside the component to
finalize the entry.
If the font is taller than the component, the text label input area becomes as tall as the
font.
If the 64-character limit is exceeded, the characters over the limit are deleted.
The following restrictions apply to the attribute settings of label components.
• [Visible] can only be set when [Depend ID] is set to [None].
List of Settings
Refer to Section 3.3 for attributes without explanations in the list of settings.
Attribute
Set value/choice
(Underlined items are initial
set values)
Description, conditions
X
DX1000: 0 to 318
DX2000: 0 to 638
This is the X-coordinate of the left side of the component.
X = 0 for X < 0
X = (Max.
width
*1
– Width) for (X + Width) > Max. width
*1
Y
DX1000: 24(0) to 238
DX2000: 40(0) to 478
( ) = Status area set to No
display
This is the Y-coordinate of the upper side of the component.
Y = Min. Y
*2
for Y < Min. Y
*2
Y = (Min. Y
*2
+ Max. height
*3
– Height) for (Y + Height) > (Min. Y
*2
+
Max. height
*3
)
*1
DX1000 max. width = 320, DX2000 max. width = 640
*2
DX1000 min. Y = 24(0), DX2000 min. Y = 40(0), ( ) = Status area set to No display
*3