3.5 Attributes of Digital Components
The following limitations exist for setting of attributes for digital components.
• [Visible] can only be set when [Depend ID] is set to [None].
• Unit font setting is not possible when Unit display is [Off].
• When the synchro target is [Switch], alarm level setting is not possible.
• When Group control is [None], the group control order cannot be set.
List of Settings
Refer to Section 3.3 for attributes without explanations in the list of settings.
Attribute
Set value/choice
(Underlined items are initial
set values)
Description, conditions
X
DX1000: 0 to 318
DX2000: 0 to 638
This is the X-coordinate of the left side of the component.
X = 0 for X < 0
X = (Max.
width
*1
– Width) for (X + Width) > Max. width
*1
Y
DX1000: 24(0) to 238
DX2000: 40(0) to 478
( ) = Status area set to No
display
This is the Y-coordinate of the upper side of the component.
Y = Min. Y
*2
for Y < Min. Y
*2
Y = (Min. Y
*2
+ Max. height
*3
– Height) for (Y + Height) > (Min. Y
*2
+
Max. height
*3
)
Width
DX1000: 2 to 320
DX2000: 2 to 640
This is the component width.
Width = 2 for width < 2
X = (Max. width
*1
– Width) for width < Max. width*
1
and (X + Width) >
Max. width
*1
Width = Max. width
*1
, X = 0 for width ≥ Max. width
*1
*1
DX1000 max. width = 320, DX2000 max. width = 640
*2
DX1000 min. Y = 24(0), DX2000 min. Y = 40(0), ( ) = Status area set to No display
*3
DX1000 max. height = 216(240), DX2000 max. height = 440(80), ( ) = Status area set to No display