Yokogawa Button Operated DX2000 User Manual
Page 71
3-10
IM 04L41B01-62EN
Attribute
Set value/choice
(Underlined items are initial
set values)
Description, conditions
Height
DX1000: 2 to 216(240)
DX2000: 2 to 440(480)
( ) = Status area set to No
display
This is the component height.
Height = 2 for height < 2
Y = (Min. Y
*2
+ Max. height
*3
– Height) for height < Max. height
*3
and (Y
+ Height) > (Min. Y
*2
+ Max. height
*3
)
Height = Max. height
*3
, Y = Min. Y
*2
for height ≥ Max. height
*3
Digital font
[Font5], [Font6], [Font8],
[Font12], [Font16], [Font32]
This is the character size for the digital value of a component.
The initial setting is [Font8] for DX1000 and [Font12] for DX2000.
Channel font
TagNo./Channel :
[Font5], [Font6], [Font8],
[Font12], [Font16]
TagNo.: [Font5], [Font12],
[Font16]
This sets the character size for Tag No., Tag Comment, and Channel
No.
The initial setting is [Font6] for DX1000 and [Font8] for DX2000.
Unit display
[Off], [On]
Display/No display is selected for the component unit.
Unit font
[Font5], [Font6], [Font8],
[Font12], [Font16]
This is the character size for Unit display. Setting is not possible when
“Unit display” is [Off].
The initial setting is [Font6] for DX1000 and [Font8] for DX2000.
Alarm display
[Off], [On]
This selects display/no display for the alarm indicator.
The alarm display marks correspond to level 1, level 2, level 3, and
level 4 from the top.
Display is made in the lime color when Alarm is Off and in the color
set for each level (red, orange, yellow or pink) when Alarm is On.
2 Line display
[Off], [On]
This selects tag display with division into two lines or no division.
Off: Display divided into two lines is not made.
On: Display divided into two lines
*1
DX1000 max. width = 320, DX2000 max. width = 640
*2
DX1000 min. Y = 24(0), DX2000 min. Y = 40(0), ( ) = Status area set to No display
*3
DX1000 max. height = 216(240), DX2000 max. height = 440(80), ( ) = Status area set to No display
Synchronize action
►Section 3.3
3.5 Attributes of Digital Components