Yokogawa Button Operated DX2000 User Manual
Page 119
3-58
IM 04L41B01-62EN
Note
•
Some time may be required until display data are displayed. Please do the following if you
want to shorten the time.
•
If All Channel display is On, set it to Off.
•
When displaying data compressed in direction of the time axis, lower the compression
ratio or reduce the number of trend components.
• When trend components are arranged superposed with push button components,
communication input components, and switch components, arrange the components so
that they are not superposed. When parts are arranged without gaps, they can overlap.
Keep a gap of at least 1 dot between parts.
• When the “Compress ratio” for trend components is set to [2] or higher, the old waveform
screen may disappear and an intermediate waveform may be displayed in case of display
switching with trend display at the DX recorder. This is caused by a limitation of the internal
memory capacity, and it is no abnormality. The data are written to the internal memory.
List of Settings
Refer to Section 3.3 for attributes without explanations in the list of settings.
Attribute
Set value/choice
(Underlined items are initial
set values)
Description, conditions
X
DX1000: 0 to 318
DX2000: 0 to 638
This is the X-coordinate of the left side of the component.
X = 0 for X < 0
X = (Max.
width
*1
– Width) for (X + Width) > Max. width
*1
Y
DX1000: 24(0) to 238
DX2000: 40(0) to 478
( ) = Status area set to No
display
This is the Y-coordinate of the upper side of the component.
Y = Min. Y
*2
for Y < Min. Y
*2
Y = (Min. Y
*2
+ Max. height
*3
– Height) for (Y + Height) > (Min. Y
*2
+
Max. height
*3
)
Width
DX1000: 2 to 320
DX2000: 2 to 640
This is the component width.
Width = 2 for width < 2
X = (Max. width*
1
– Width) for width < Max. width
*1
and (X + Width) >
Max. width
*1
Width = Max. width
*1
, X = 0 for width ≥ Max. width
*1
Height
DX1000: 2 to 216(240)
DX2000: 2 to 440(480)
( ) = Status area set to No
display
This is the component height.
Height = 2 for height < 2
Y = (Max. height*
3
– Height) for height < Max. height
*3
and (Y +
Height) > Max. height
*3
Height = Max. height
*3
, Y = 0 for height ≥ Max. height
*3
Batch group number
Setting range: 1 to multi-
batch number set by the
basic settings of the DX
recorder
DX1000: [1] to [6]
DX2000 standard memory:
[1] to [6]
DX2000 expanded memory:
[1] to [12]
This is the batch group number that can be selected within the range
of the number of multibatches set in the basic settings on the DX
recorder.
This item cannot be set when multi-batch of the DX recorder is OFF.
Display Grp no
when multi-batch is Off.
DX1000: [1] to [10]
DX2000: [1] to [36]
when multi-batch is On.
DX1000: [1] to [6]
DX2000: [1] to [12]
Display on the builder screen of the DX recorder is made as “Group
No.”.
The group selection range differs according to the batch.
Direction
[SET], [Horizontal], [Vertical]
This is the waveform flow direction.
SET: Setting of the DX recorder
Vertical: Vertical waveform direction
Horizontal: Horizontal waveform direction
*1
DX1000 max. width = 320, DX2000 max. width = 640
*2
DX1000 min. Y = 24(0), DX2000 min. Y = 40(0), ( ) = Status area set to No display
*3
DX1000 max. height = 216(240), DX2000 max. height = 440(80), ( ) = Status area set to No display
3.28 Attributes of Trend Components