7. pArAMETEr dESCrIpTION

7-6

IM 01R04B04-00E-E 8th edition March 01, 2011 -00

All Rights Reserved. Copyright © 2003, Rota Yokogawa

parameter

data
form

data range

dec.

point

Unit

r : read
W : write
Exe :
execute

reset

Master

reset

power on

default

Disp contrast

Select

-5

-

-

R/W

X

0

-4

-3

-2

-1

0

1

2

3

4

5

Disp Period

Select

0.5 s

-

-

R/W

X

1.0 s

1.0 s

2.0 s

Flow direction

Select

Forward

-

-

R/W

X

Forward

Reverse

Mass flow unit

Select

g/s

-

-

R/W

X

RCCS30…33
kg/h

g/min

RCCS34…39/XR
t/h

g/h

kg/s

kg/min

kg/h

kg/d

t/min

t/h

t/d

lb/s

lb/min

lb/h

lb/d

Mass flow format

Select

xxxxxxx

-

-

R/W

X

xxxx.XX

xxxxx.X

xxxx.XX

xxx.XXX

xx.XXXX

x.XXXXX

Mass flow LRV

Decimal

-Qmax to Qmax

0 to 5

Mass flow unit

R/W

X

0

Mass flow URV

Decimal

-Qmax to Qmax

0 to 5

Mass flow unit

R/W

X

Qnom

Mass flow damping

Decimal

0 to 200

1

Sec.

R/W

X

3

Mass flow lowcut

Decimal

0 to 10% of Qmax

0 to 5

Mass flow unit

R/W

X

0

Mass flow alm 1 sel

Select

No function

-

-

R/W

X

No function

More than

Less than

Mass flow alm 1 crit

Decimal

-110% to 110% of
URV

0 to 5

Mass flow unit

R/W

X

0

Mass flow alm 2 sel

Select

No function

-

-

R/W

X

No function

More than

Less than

Mass flow alm 2 crit

Decimal

-110% to 110% of
URV

0 to 5

Mass flow unit

R/W

X

10

Mass flow fix val sel

Select

Inhibit

-

-

R/W

X

Inhibit

Enable

Mass flow fixed val

Decimal

0 to Qnom

0 to 5

Mass flow unit

R/W

X

0