2 warranty, 3 instruction according emc, 2 warranty -3 – Yokogawa RotaMASS 3-Series User Manual
Page 11: 3 instruction according emc -3

1. INTrOdUCTION
1-3
IM 01R04B04-00E-E 8th edition March 01, 2011 -00
All Rights Reserved. Copyright © 2003, Rota Yokogawa
1.2 Warranty
• The warranty terms of this instrument that are
guaranteed are described in the quotation. We
will make any repairs that may become neces-
sary during the guaranteed term free of charge.
• Please contact our sales office if this instrument
requires repair.
• If the instrument is faulty, contact us with com-
plete details about the problem and the length of
time it has been faulty, and state the model and
serial number. We would appreciate the inclu-
sion of drawings or additional information.
• The results of our examination will determine
whether the meter will be repaired free of charge
or on an at-cost basis.
The guarantee will not apply in the following
cases:
• Damage due to negligence or insufficient main-
tenance on the part of the customer.
• Problems or damage resulting from handling,
operation or storage that violates the intended
use and specifications.
• Problems that result from using or performing
maintenance on the instrument in a location that
does not comply with the installation location
specified by Yokogawa.
• Problems or damage resulting from repairs or
modifications not performed by Yokogawa or
someone authorized by Yokogawa.
• Problems or damage resulting from inappropri-
ate installation after delivery.
• Problems or damage resulting from disasters
such as fires, earthquakes, storms, floods, or
lightning strikes and external causes.
1.3 Instruction according
EMC
The ROTAMASS Coriolis flowmeter is conform
to the European EMC Guideline and fulfills the
following standards:
EN 61326-1: 2006;
EN 61326-2-3: 2006;
EN 61000-3-2: 2006;
EN 61000-3-3: 1995+A1+A2
ROTAMASS is a class A product and should be
used and installed properly according to the EMC
Class A requirements
Installation
The function ground terminal or the PE- terminal
have to be connected to protective ground to
ensure electro-magnetic interference protection.
To ensure the EMC specifications the following
measures must be carried out :
1. Put the power cables through the ferrite core
clamp before connecting to the terminals as shown
in chapter ´ Installation ´ (Power supply wiring).
2. Put the I/O- cables through the ferrite core
clamp before connecting to the terminals as shown
in chapter ´ Installation ´ (Power supply wiring).
3. Connect protective ground conductor of power
supply to PE- terminal in the terminal box (see
chapter ´ Installation ´ (Power supply wiring).
4. In case of Explosion proof type instrument, fur-
ther requirements are described in chapter 9
“EXPLOSION PROTECTED TYPE INSTRUMENTS”.
The description in this chapter is prior to other de-
scriptions in this instruction manual.
restriction on Use of radio Transceiver :
IMPORTANT
Although the products has been designed to
resist high frequency electrical noise, if a radio
transceiver is used near the flowmeter or its
external wiring, the transmitter may be affected by
high frequency noise pickup. To test for such
effects, bring the transceiver in use slowly from a
distance of several meters from the flowmeter,
and observe the measurement loop for noise
effects. Thereafter, always use the transceiver
outside the area affected by noise.
CAUTION