beautypg.com

7 connecting hart- communication, 8 flowmeters with intrinsic safe outputs, 7 connecting hart- communication -22 – Yokogawa RotaMASS 3-Series User Manual

Page 50: 8 flowmeters with intrinsic safe outputs -22, Hazardous area, Safe area rotamass /kf2

background image

4. INSTAllATION

4-22

IM 01R04B04-00E-E 8th edition March 01, 2011 -00

All Rights Reserved. Copyright © 2003, Rota Yokogawa

Example of installation :

F418.EPS

Hazardous area

Iout +

Iout -

R barrier

4-20mA

Vin

V out

Ground

Safe area

ROTAMASS
/KF2

R load

4.8.7 Connecting HArT- Communication

HART communication is available on analog output 1 and the HART-communicator is connected via load
resistance (230 ... 600 Ω) as shown on the figure below.

HART

Communicator

HART

Communicator

HART

Communicator

Intermediate

terminals

4 to 20mA DC

signal trans-

mission line

Receiving

instrument

Terminal board

Control room

F417.EPS

ROTAMASS

4.8.8 Flowmeters with intrinsic safe outputs

ROTAMASS with option /KF2 has one intrinsic safe current output and one intrinsic safe pulse / status
output. The Ex-data of this output can be found in chapter 9.1.
The second current output, the second pulse / status output and the status input are not available.
The concerning parameters in the menu are not visible.

Current output : The intrinsic safe current output is passive and an external power supply with shunt-diode
type barrier or isolation type barrier should be connected.