8. SElF-dIAgNOSTIC ANd TrOUBlESHOOTINg
8-11
IM 01R04B04-00E-E 8th edition March 01, 2011 -00
All Rights Reserved. Copyright © 2003, Rota Yokogawa
8.7.8 discrepancy of output signals to the assigned measurand
no
yes
Measured temperature
values OK ?
Converter fault.
Contact the nearest
YOKOGAWA office or
service center.
Check the electronics:
Connect Pt100 simulator to terminals TP1, TP2, TP3 in converter
RCCF31 terminal box.
TP1 : + power, + sensor
TP2 : - sensor
TP3 :
Check your reference
temperature.
F88.EPS
- power
no
yes
no
yes
Is the setting of the
doubtful output signal
correct ?
Make correct parameter
setting.
Check output according
chapter 8.4.
Output OK ?
Contact the nearest
YOKOGAWA office or
service center
Check measurand.
F89.EPS
- EJA120A (31 pages)
- EJA130A (47 pages)
- EJA120A (40 pages)
- EJA438 (5 pages)
- EJA120A (6 pages)
- EJA115 (85 pages)
- EJA120A (47 pages)
- EJA120A (79 pages)
- EJA130A (2 pages)
- EJA130A (4 pages)
- EJA210A (70 pages)
- EJA130A (4 pages)
- EJA430A (78 pages)
- EJA210E (9 pages)
- EJX115A (55 pages)
- EJA210E (41 pages)
- EJA210E (96 pages)
- EJA210E (52 pages)
- EJA210E (89 pages)
- EJA210E (170 pages)
- EJX120A (4 pages)
- EJX910A (55 pages)
- EJX910A (175 pages)
- EJX910A (83 pages)
- EJX910A (9 pages)
- EJX910A (103 pages)
- FlowNavigator Software (163 pages)
- EJA530A (67 pages)
- EJA120A (83 pages)
- EJX530A (52 pages)
- EJA110E (4 pages)
- EJA110E (85 pages)
- EJX120A (85 pages)
- EJA118 (76 pages)
- EJX118A (64 pages)
- EJA438 (72 pages)
- EJA430E (85 pages)
- EJX430A (40 pages)
- EJX430A (76 pages)
- EJA430E (7 pages)
- EJX430A (6 pages)
- EJA430E (41 pages)
- EJA430E (96 pages)
- EJX438A (10 pages)
- ADMAG AXR (194 pages)