4.6 Mounting of converter rCCr31 in a subrack

If the remote rack mount converter RCCR31 was not ordered with option /SR1 or /SR2, the customer has
to mount it to an own 19´´ subrack. The terminal board must be fixed by 6 screws (M2.5x10) to the rear
side of the subrack.

The RCCR31 rack cassette must be inserted into the subrack.

4.7 Alteration of display (rCCT3 / rCCF31)

LCD display can be turned its direction with respect to piping configurations.
Removing four screws, adjusting display’s orientation and fixing the screws tightly again as shown in figure
below.

Fix the lock screw for use in hazardous area. After modification the user must ensure that the cover is
screwed down tightly to maintain the IP rating of the housing, failure to do so may allow moisture
ingress and failure of electronic components.

F43.EPS

Lock screw for cover (Ex d)

IMPORTANT