3 operation, 4 maintenance and repair, 3 operation -24 – Yokogawa RotaMASS 3-Series User Manual
Page 216: 4 maintenance and repair -24

9. EXplOSION prOTECTEd TYpE INSTrUMENTS
9-24
All Rights Reserved. Copyright © 2003, Rota Yokogawa
IM 01R04B04-00E-E 8th edition March 01, 2011 -00
9.3.3 Operation
If the cover of the converter RCCF31 / RCCT3 has to be opened, following instructions must be followed.
CAUTION
1. Confirm that the power cables to the instrument are disconnected.
2. Wait 15 minutes after power is turned off before opening the covers.
3. The covers of display side and terminal box are fixed with special screws, please use Hexagonal
wrench to open the covers.
4. Be sure to lock the cover with special screw using the Hexagonal Wrench after
tightening the cover (see drawing chapter 4.3).
5. Before starting the operation again, be sure to lock the cover with the locking screws
.
6. Prohibition of specification changes and modifications. Users are prohibited from making any modifications
of specifications or physical configuration, such as adding or changing the configuration of external wiring
ports.
9.3.4 Maintenance and repair
WARNING
The instrument modification of parts replacement by other than authorized representatives of YOKOGAWA
is prohibited and will void the certification.