<4. Preparation>
4-22
IM 01C25R51-01E
Figure 4.27 HART Modem configuration
F0428E.ai
Select COM port number.
Figure 4.28 COM port
Please refer to FieldMate User's manual for details.
(2) Communication address setting on FieldMate
In FieldMate, the default setting of maximum scan value of communication address is “0”.
If the transmitter’s address is other than “0”, FieldMate cannot distinguish the transmitter.
Therefore, the setting should be changed to the correct value.
1. Click the [Tool] → [HART Modem Configuration..] at FieldMate window.
2. Select address number.
3. Click the [OK] button.
F0429E.ai
Maximum value of communication
Address for scaning
Figure 4.29 Address Setting
Please refer to FieldMate for detail.