Error message, 1 error message, Error message -1 – Yokogawa EJX930A User Manual
Page 143

<10. Error Message>
10-1
IM 01C25R51-01E
10. Error Message
Error message is shown in both pop up message and error log file
(EJXMVTool.log/DYFMVTool.log).
Figure 10.1 Error message example
In case of Physical Property error, code and sub code is shown in error log file
(EJXMVTool.log/DYFMVTool.log).
10.1 Error Message
Table 10.1
Error message
Code Sub code
Information Message
Explanation
Recovery
600
8
[Display]
The range that specified in the step of
Fluid Operating Range Setup is too
narrow. Expand the range of Pressure
or Temperature.
[Log file]
Physical Calc lib Error - ERR_RANK
Rank deficient
The temperature or pressure
range which was set by the
user at the Fluid Operating
Range Setup is too narrow. Try
another range value.
This manual is related to the following products: