<3. Functional Specification>
3-5
IM 01C25R51-01E
3.4.2 Flow Parameter Management (Flow Configuration
Wizard)
(1) EJXMVTool
(a) Auto Compensation Mode
Configuration of the fluid physical properties and primary device for the EJX
Multivariable Transmitter can be performed using a dialog window. Refer to Section 7.1.
(b) Basic Mode
Flow operation and density compensation are performed conventionally, with the flow
factors being input manually. Refer to Section 7.2.
(c) File management
Parameters are imported and exported using following files.
xmv file: import / export User Flow Parameters and Device Flow Parameters
prm file: Import HART Device Flow Parameters (only for FSA210 user)
(d) Report function
Export User Flow Parameters and Device General Parameters in CSV file format.
(2) DYFMVTool
(a) Detail (Gas / Liquid) Compensation Mode
Configuration of the fluid physical properties for the digitalYEWFLO Vortex Flowmeter
can be performed using a dialog window. Refer to Section 8.1.
(b) Steam Compensation Mode
Flow operation and density compensation are performed, with the flow factors inside
digitalYEWFLO Vortex Flowmeter. Refer to Section 8.2.
(c) Simple (Gas / Liquid) Compensation Mode
Flow operation and density compensation are performed conventionally, with the flow
factors being input manually. Refer to Section 8.2.
(d) File management
Parameters are imported and exported using following files.
vmv file: import / export User Flow Parameters and Device Flow Parameters
(e) Report function
Export User Flow Parameters and Device General Parameters in CSV file format.