beautypg.com

Watlow Series F4P User Manual

Page 101

background image

Wa t l o w S e r i e s F 4 P

C o m m u n i c a t i o n s

9 . 7

581

Integral 1B, PID Set 4

r/w

0 to 9999 minutes in hundredths

591

Integral 1B, PID Set 5

r/w

0 to 9999 minutes in hundredths

704

Latching, Alarm Output 1

r/w

0

Alarm Self-clears

1

Alarm Latches

721

Latching, Alarm Output 2

r/w

0

Alarm Self-clears

1

Alarm Latches

1914

LED Intensity, Process Display

r/w

0 to 15

1515

Line Frequency, Diagnostic

r

xx

715

Low Power Limit, Control Output 1A

r/w

0% to High Limit-1

732

Low Power Limit, Control Output 1B

r/w

0% to High Limit-1

710

Low Scale, Retransmit Output 1

r/w

-19999 to 30000 (minimum sensor range)

727

Low Scale, Retransmit Output 2

r/w

-19999 to 30000 (minimum sensor range)

454

Manual to Auto Transfer, System

r/w

0

Restore Set Point

1

Reverse Bumpless

5

Manufacturing Date, Diagnostic

r

xxxx

453

Maximum Transfer Cool, System

r/w

-100% to 0%

452

Maximum Transfer Heat, System

r/w

0% to 100%

4501-17

Message 1 (Line 01, Char 01-17), Static Message r/w

4521-37

Message 1 (Line 02, Char 01-17), Static Message r/w

4541-57

Message 1 (Line 03, Char 01-17), Static Message r/w

4561-77

Message 1 (Line 04, Char 01-17), Static Message r/w

4581-97

Message 2 (Line 01, Char 01-17), Static Message r/w

4601-17

Message 2 (Line 02, Char 01-17), Static Message r/w

4621-37

Message 2 (Line 03, Char 01-17), Static Message r/w

4641-57

Message 2 (Line 04, Char 01-17), Static Message r/w

4661-77

Message 3 (Line 01, Char 01-17), Static Message r/w

4681-97

Message 3 (Line 02, Char 01-17), Static Message r/w

4701-17

Message 3 (Line 03, Char 01-17), Static Message r/w

4721-37

Message 3 (Line 04, Char 01-17), Static Message r/w

4741-57

Message 4 (Line 01, Char 01-17), Static Message r/w

4761-77

Message 4 (Line 02, Char 01-17), Static Message r/w

4781-97

Message 4 (Line 03, Char 01-17), Static Message r/w

4801-17

Message 4 (Line 04, Char 01-17), Static Message r/w

3060

Message Display Time, Digital Input 1

r/w

0 to 999

3061

Message Display Time, Digital Input 2

r/w

0 to 999

3062

Message Display Time, Digital Input 3

r/w

0 to 999

3063

Message Display Time, Digital Input 4

r/w

0 to 999

0

Model, Diagnostic

r

5280

4P

3200-09

Name (Char 01-10), Alarm Output 1

r/w

ASCII codes A to Z, 0 to 9, space

3210-19

Name (Char 01-10), Alarm Output 2

r/w

ASCII codes A to Z, 0 to 9, space

3000-06

Name (Char 01-07), Digital Input 1

r/w

ASCII codes A to Z, 0 to 9, space

3010-16

Name (Char 01-07), Digital Input 2

r/w

ASCII codes A to Z, 0 to 9, space

3020-26

Name (Char 01-07), Digital Input 3

r/w

ASCII codes A to Z, 0 to 9, space

3030-36

Name (Char 01-07), Digital Input 4

r/w

ASCII codes A to Z, 0 to 9, space

5506-15

Offset Point 01-10, Analog Input 1, rw

r/w

-19999 or Input Offset (x-1) Value
+ 1 to Input Offset (x+1) Value - 1 or 30000

5516-25

Offset Point 01-10, Analog Input 2, r/w

r/w

-19999 or Input Offset (x-1) Value
+ 1 to Input Offset (x+1) Value - 1 or 30000

5526-35

Offset Point 01-10, Analog Input 3, r/w

r/w

-19999 or Input Offset (x-1) Value
+ 1 to Input Offset (x+1) Value - 1 or 30000

5572

Offset Type, Analog Input 1

r/w

0

Single Linear

1

Multiple Point

5573

Offset Type, Analog Input 2

r/w

0

Single Linear

1

Multiple Point

5574

Offset Type, Analog Input 3

r/w

0

Single Linear

1

Multiple Point

5536-45

Offset Value 01-10, Analog Input 1

r/w

-1000 to 1000

5546-55

Offset Value 01-10, Analog Input 2

r/w

-1000 to 1000

5556-65

Offset Value 01-10, Analog Input 3

r/w

-1000 to 1000

904

Open Loop Detect, System

r/w

0

Off

1

On

1308

Operations, Alarm Set Point, Set Lockout

r/w

0

Full Access

1

Read Only

2

Password

3

Hidden

1306

Operations, Autotune PID, Set Lockoutr/w

r/w

0

Full Access

1

Read Only

2

Password

3

Hidden

1318

Operations, Control Set Point, Set Lockout

r/w

0

Full Access

1

Read Only

2

Password

3

Hidden

1307

Operations, Edit PID, Set Lockout

r/w

0

Full Access

1

Read Only

2

Password

3

Hidden

200

Operations Mode, Status

r/w

1

Auto Mode

2

Manual

1316

Operations, PID Crossover, Set Lockout

r/w

0

Full Access

1

Read Only

2

Password

3

Hidden

1317

Operations, Ramp Set Point, Set Lockout

r/w

0

Full Access

1

Read Only

2

Password

3

Hidden

1319

Operations, Remote Set Point, Set Lockout

r/w

0

Full Access

1

Read Only

2

Password

3

Hidden

16

Output 1A, Diagnostic

r

0

None

1

Mechanical Relay

2

SSR

3

DC

4

Process