6. T
roubleshooting
Code
Error Cause/action
0F5
Nonvolatile memory
verification error after
write
When data has been written to the nonvolatile memory, the written data is read
and compared (verified) against the written data for confirmation.
This alarm indicates that the read data does not match the written data.
Cause: [1]
Faulty
nonvolatile
memory
[2] The memory has been rewritten more than 100,000 times. (The
nominal life of the nonvolatile memory is 100,000 rewrite
operations.)
Action:
If the problem still persists after the power has been reconnected,
contact IAI.
0F6
Nonvolatile memory
timeout after write
This alarm indicates that no response was received within the specified time after
writing data to the nonvolatile memory.
Cause: [1]
Faulty
nonvolatile
memory
[2] The memory has been rewritten more than 100,000 times. (The
nominal life of the nonvolatile memory is 100,000 rewrite
operations.)
Action:
If the problem still persists after the power has been reconnected,
contact IAI.
0F8
Damaged nonvolatile
memory
Abnormal data was detected in the nonvolatile memory check after starting.
Cause: [1]
Faulty
nonvolatile
memory
[2] The memory has been rewritten more than 100,000 times. (The
nominal life of the nonvolatile memory is 100,000 rewrite
operations.)
Action:
If the problem still persists after the power has been reconnected,
contact IAI.
0FA
CPU error
The CPU is not operating correctly.
Cause: [1]
Faulty
CPU
[2] Malfunction due to noise
Action:
If the problem still persists after the power has been reconnected,
contact IAI.