IAI America PCON-PO User Manual
Page 56
44
4. Operation Using I/O Signals
(2) Command Pulse Mode
User Parameter No. 63 (Command-pulse input mode)
Name
Symbol
Unit
Input range
Default (reference)
Command-pulse input mode
MOD
-
0 to 2
1
Set a pulse-train input pattern for command pulse input (PP•/PP, NP•/NP).
* The setting of positive logic or negative logic is explained in (3), “Input Polarity in the Command Pulse Mode.”
(3) Input Polarity in the Command Pulse Mode
User Parameter No. 64 (Polarity in command-pulse input mode)
Name
Symbol
Unit
Input range
Default (reference)
Polarity in command-pulse input mode
POLE
-
0 to 1
0
Setting
Positive
logic:
0
Negative
logic:
1
Command-pulse
input pattern
Input terminal
Forward
Reverse
Setting
Negative logic
Positive logic
Forward pulse train
Reverse pulse train
Pulse train
Sign
Phase-A/B pulse train
Forward pulse trains indicate motor revolutions in the positive direction, while reverse pulse trains indicate
motor revolutions in the reverse direction.
Command pulses indicate motor revolutions, while the sign of the command indicates the rotating direction.
Phase-A/B x4 pulses of 90
° phase difference indicate both revolutions and rotating direction.
Forward pulse train
Reverse pulse train
Pulse train
Sign
Phase-A/B pulse train