beautypg.com

IAI America PCON-PO User Manual

Page 37

background image

25

3. Installation and W

iring

If a separate emergency stop circuit is provided to stop the entire system, or when multiple controllers are linked
together and each controller has a different power supply, connect external EMG relay contacts.

24-VDC control
power supply

External EMG
reset switch

External EMG circuit

Relay

Power-supply

terminal block (1st)

Power-supply

terminal block (2nd)

24-VDC input power
supply
(Max. 2 A per unit)

Power-supply

terminal block (3rd)

24-VDC input power
supply
(Max. 2 A per unit)

24-VDC input power
supply
(Max. 2 A per unit)

0 VDC

This manual is related to the following products: