2. Installation
60
Tapped mounting hole
Bracket A
Bracket B
(8) Single-guide type
Use the tapped holes in the bracket for installing an actuator of the single-guide type.
z
Applicable model: Double-guide type RGD4
Type
Tapped hole diameter
Tapped depth
Tightening torque
RA4 type
M5
8 mm
3.4 N•m