IAI America RCS2W User Manual
Page 100
4. Maintenance Inspection
92
Z phase ON
position
Mechanical end
Home position
Approx. 2 mm
The countermark on the motor
aligns with this position.
Set by the home offset parameter (SCON) or home preset
parameter (SSEL, X-SEL).
(The above value indicates the factory setting.)
1 mm
4.6.2
Replacing the Motor of the Motor Reversing Type: RA4R Type
[Items Required for Replacement]
x
Replacement motor unit
x
Allen wrenches
x
Tension gauge (capable of tensioning to 7 kgf or greater)
x
Strong string, looped (or long tie-band)
x
Scale
x
Oil-based marker pen
x
PC or teaching pendant
[Overview of Replacement]
1) Loosen the motor-unit affixing bolts to remove the belt, and replace the motor.
2) Restore the home position.
Affix the rod at a position 2 mm from the mechanical end on the home side, pass the belt, and adjust the belt to
the specified tension.
3) Perform homing using a PC or teaching pendant and check for deviation from the initial home position.
If there is a deviation, adjust the home offset if you are using an SCON controller. If you are using an SSEL or
X-SEL controller, adjust the home preset.
Replacement motor unit