BeltStati on will not power up

Confi rm that batt ery(ies) is (are) installed correctly.

When using a Lithium-Polymer rechargeable batt ery, ensure that the batt ery is fully charged.

When using alkaline AA batt eries, ensure that batt eries are fresh and are all facing the same way. Note the illustrati on

in the batt ery compartment secti on.

Press and hold the Power butt on on the back of the BeltStati on for two seconds to power ON.

BeltStati on will not pair with BaseStati on

Confi rm that the BaseStati on you are pairing with is powered ON and in Operati onal Mode, and the BeltStati on is
powered OFF. Connect the pairing cable from the BaseStati on to the BeltStati on. Turn the BeltStati on power ON.
The pairing process takes approximately four seconds.

If pairing is successful, the message “Pairing Complete” will appear on the BeltStati on LCD for approximately fi ve
seconds and the BeltStati on name will appear in the fi rst available slot on the BaseStati on LCD. The BaseStati on
name will appear on the BeltStati on LCD. If pairing is not successful no message will appear.

If pairing is not successful, try to pair a diff erent BeltStati on with the BaseStati on. If neither of the BeltStati ons
will pair, substi tute a new Pairing cable.

If successful pairing any BeltStati on with the BaseStati on, try the following procedure on the BeltStati on that will
not pair:

»

Restore memory setti ngs to Factory Defaults by pressing MENU

»

Select “Belt Setti ngs,” select “Tech Menu,” press ENTER to proceed

»

Select “Set Defaults,” select

Restore Factory Defaults

, press ENTER to confi rm and press MENU to exit

If sti ll not successful, repeat the above procedure but select

Clear Memory

to delete all memory setti ngs, pairings,

and user setti ngs.

See “Factory Defaults” secti on for more detail.

If no BeltStati on will pair with the BaseStati on, reset the BaseStati on memory to “Factory Defaults”.

The fi nal opti on is to select “Clear Memory” to fully reset the BaseStati on. All BeltStati on pairings will be lost with the
“Clear Memory” opti on.

See “Factory Defaults” secti on for more detail.

BeltStati on will not log into BaseStati on

Confi rm that the BeltStati on is powered ON and has a batt ery with ample charge.

Confi rm that the proper BaseStati on is selected on the BeltStati on’s “Select Base” menu.

Confi rm that there is an available slot on the BaseStati on.

Check Stati c and Dynamic slot display setti ngs on the BaseStati on. If Stati c is selected check the BeltStati on slot

assignment.

Determine if any BeltStati on is logged onto the BaseStati on.

Re-pair the BeltStati on to the BaseStati on.

Att empt to log into another BaseStati on, if available.

Follow the memory reset procedure under “Factory Defaults.”