Version numbers and ip address – Clear-Com V12PDDXY User Manual
Page 90
Version numbers and IP address
Figure 96: Diagnostic menu (offline display) for rack mounted panels
Figure 97: Diagnostic menu (offline display) for desktop panels
The version number displayed in the DIAGNOSTIC menu is for the panel application only.
To obtain the version numbers of all panel firmware and the IP address of the V-Series
panel, you must take the panel off line.The information given (from the example information
in Figure 95 and Figure 96 above) is as follows:
Example diagnostic
information
Description / comments
M 0.20.0
Module application code version
U 0.0.11
Panel boot loader version
K2.6.16
Panel kernel version
A0.19.0
Panel application version
172.16.86.101
Panel IP address (if set, otherwise blank).
Table 23: Example diagnostic information
90
V-Series Panels User Guide