Figure 24: Fast Key Assign for desktop panels
5.2.1 The Dial code
The fast key assign requires 3 to 5 key presses for a dial code number to use. The dial code
number will be displayed on the reply key as the user is dialling it. The first port number dial
code will be 1 and all entity types will be 1 indexed.
5.2.2 Dial code validation
To terminate a Dial Code number the user must press the * key. At this point the Dial Code
number is verified to see if the user is allowed to assign the entity to the panel through the
sort group rules. If it is an invalid or disallowed operation then “Invalid” will be displayed on
the reply key. If it is valid, then the label for the entity will be displayed on the reply key and
the key labels which it can be assigned to will flash. The rack will determine if the entity is
assignable by looking in the entity table to see if the “Protect Port from Assignment” bit has
been set and if the talk and listen bits are cleared. Also the Sort groups will be checked to
see if the user panel is allowed to assign the entity.
Whether the key assigned has its talk or listen bits set will be determined by the default
settings on the port set in ECS. Note if the talk and listen bits are set, a Talk + Listen key will
be configured not a Talk + Forced Listen. On a lever or rotary V-Series panel the talk will be
placed on the talk key and the listen on the listen key. The rotary encoder panel will also
support talk forced listen. The force listen will be assigned to the encoder key and the talk to
the push button key.
Sort groups
If the destination is a member of a valid local sort group, you can scroll the members of the
sort group until you reach the desired destination by using the up/down buttons or rotary
controller on the Reply key. Any member of the sort group may be selected for assignment.
Note:
If the destination port is a member of a sort group that is blocked for the panel the word
BLOCKED is displayed in the reply key. Sort group permissions are set in ECS / EHX. For
more information, see your ECS / EHX documentation.
42