7 la (listen again), La (listen again) – Clear-Com V12PDDXY User Manual
Page 171
8.3.7 la (Listen Again)
The la command allows various controls for the Listen Again system to be displayed and
changed.
Display 2 shows the parameter name.
Display 3 shows the parameter value.
Figure 198: la (Listen Again) display
The parameter names and values are shown below:
Parameter
Description / comments
threshold
The signal level in dB needed to trigger the Listen Again
recording
maxsilence
The maximum time in ms that silence will not cause
fragmentation of a message
stale
The time in seconds after which a message will be deleted
startsil
The duration in ms of silence preceding message playback
starttone
The duration in ms of the start tone during playback
endsilence
The duration in ms of the silence after playing back a message
endtone
The duration in ms of the end of messages tone during playback
Table 54: la parameters and values
171