beautypg.com

1 using rotary panel keys, 2 rotary panel reply key, Using rotary panel keys – Clear-Com V12PDDXY User Manual

Page 35: Rotary panel reply key

background image


4.17.1

Using rotary panel keys

By default, the talk label is displayed on a key, unless a listen only label is configured for the
key.

In assignment panel mode, the talk labels are shown on possible IFB destinations and the
listen labels are shown when the user is selecting an IFB source.

The rotary control and talk button normally default to latching unless the non-latching option
is configured in ECS / EHX under Global Settings (Latch Disable set to True) for the
destination port.

In the default state (latching), pressing the rotary control or talk button momentarily latches
the key.

If you hold the rotary control or talk button for more than 200ms, the key does not latch and
the connection terminates as soon as the key is released.

When the rotary control is inactive, the center of the control is lit

dim

green

. When the talk

button is inactive, the button is lit

dim red

.


If the brightness control is turned down further, the dimmed lighting of the rotary control and
talk button is turned off entirely.

When you press the rotary control to establish a listen route, the center of the control is lit

bright green

. When you press a talk button to establish a talk route, the button is lit

bright

red

.


To cancel the connection press the rotary control or talk button.
.
An incoming call is signalled by a

flashing red

Reply key talk button. To pick up the call

press the reply key talk button.

4.17.2

Rotary panel Reply key

The Reply key on a rotary panel can be overwritten with other talk and listen labels in ECS /
EHX without being deleted. This enables the creation of:

• 12 listen and 12 talk pairs for each 1RU panel.

• 24 listen and 24 talk pairs for each 2RU panel.


If you enter Menu mode and the reply key has been overwritten / is no longer available, the
Assignment Panel (AP) functions are disabled. If the labels placed on the Reply key are
removed in ECS / EHX, the Reply key becomes available again and Assignment Panel
functions are restored.

You can use the Reply key rotary control to scroll through the Reply key stack if more than
one call is present on the answerback stack. To move to the next call, turn the rotary control
clockwise. To return to the previous call, turn the rotary control anticlockwise.