The MESSAGE menu provides access to the following menu options / actions:

Menu options /
actions

Description / comments

RECORD

When you press the RECORD button, you can record up to 10
seconds of audio from the microphone into an audio file on the panel.

Text inverts while the button is pressed.

REVIEW

When you press the REVIEW button, the outgoing message is played
to the currently selected output device (Headset or Loudspeaker).

Text inverts while the button is pressed.

PLAY

When you press the PLAY button, the outgoing message is output to
the route configured by ECS / EHX. This will normally be Matrix 1 or
Matrix 2 but may be the EXT1 or EXT2 output.

Text inverts while the button is pressed.

ERASE

When you press the ERASE button, the current outgoing message is
erased.

Configurable
Messaging

Enables access to the Messaging menu on v-series panels.

If the tick box is disabled, the panel will not show the MESSAGE menu.

If the option is enabled, the panel is in the messaging menu and the
PLAY button is on:

1. Panels with a listen to this panel will hear the recorded audio.

2. Another panel talking to this panel will also get a listen route and
will be able to hear the recorded message. Note that only a maximum
of 10 panels simultaneously talking to that panel will hear the recorded
message if the PLAY button is on.

Figure 63: MESSAGE menu options

Tip:

To return to the LOCAL PREF menu, press the Reply key / Reply key talk button

(MESSAGE).

Note:

You can use the recorded output message to verify audio paths between ports.

Select a talk path set up on the panel, then enter the MESSAGE menu and press PLAY. If
the talk path connects to another panel, the message is heard as an incoming talk on the
target panel.

65