Clear-Com V12PDDXY User Manual
Page 115
If the IVC-32 card is reachable, but another error occurs that indicates a more detailed
networking or configuration issue, then the error code starts with 6:
Code
Error / status message Description / comments
Err 6:0
Local call cleared
Err 6:1
Call rejected locally
Err 6:2
Locally declined
Err 6:3
Remote cleared call
IVC-32 has cleared the call
Err 6:4
Remote refused call
IVC-32 has refused to accept the call from the
panel
Err 6:5
Remote ans. timeout
The IVC-32 has not replied to the call within the
timeout period
Err 6:6
Remote stopped
IVC-32 card has stopped responding
Err 6:7
Transport cleared
Err 6:8
Transport connection
Err 6:9
Gatekeeper cleared
Err 6:10
Cannot find user
The user name specified by the panel is not
known to the target system
Err 6:11
Not enough bandwidth
The network did not have enough bandwidth
available for a connection
Err 6:12
No common capabilities
Err 6:13
Call was forwarded
Err 6:14
Bad password
The panel name or the password is incorrect
Err 6:15
Local end busy
Network congested
Err 6:16
Local end busy
Network congested
Err 6:17
Remote end busy
Network congested or IVC-32 busy
Err 6:18
Remote end busy
Network congested or IVC-32 busy
Err 6:19
Remote party unavail.
Target IVC-32 could not be contacted
Err 6:20
Remote disconnected
OK
The IVC-32 has terminated the connection
115
V-Series Panels User Guide