INT.ERROR
Internal error
None, device faulty
PV FAULT
Signal error, actual value,
Check signal
process controller
Error messages on execution of the function X.TUNE
Display
Causes of error
Remedy
X.ERR 1
No compressed air connected
Connect compressed air
X.ERR 2
Air pressure failure during
AUTOTUNE
Check compressed air supply
X.ERR 3
Actuator or actuator system
None, device faulty
leaky on exhaust side
X.ERR 4
Actuator system leaky on
None, device faulty
pressurized side
X.ERR 5
The dead band of the internal position
Check alignment of the axle of the
sensor system is exceeded
SIDE Control
(S/HART) and
correct (see chapter
Installation)
X.ERR 6
The end positions for
POS-MIN and
Check whether the allocation of
POS-MAX are too near together.
the end positions to
POS-MIN and
POS-MAX via the function TUNE-
POS is correct.
If incorrect:
execute
TUNE-POS again.
If correct:
TUNE-POS with this arrangement
of the end positions is not possible
since they are too close together.
X.ERR 7
False allocation of
POS-MIN and
To determine
POS-MIN and
POS-MAX
POS-MAX, move the actuator in
each case in the direction shown