Profibus pa) configuration parameters – Burkert Type 8635 User Manual
Page 116
114 - 8635
C
ONFIGURATION FOR
B
US
C
OMMUNICATION
(PROFIBUS PA)
Configuration parameters
N: Non-volatile parameter
S: Static revision counter parameter
D: Dynamic parameter
C: Constant parameter
Parameter
Slot
index
Index
abso-
lute
Read
Write
Type
Size
byte
Memory
class
Device management
Directory_object_header
1
0
X
OSTRING
12
C
Composite_directory_entrie
1
1
X
OSTRING
24
C
Physical Block
Block object
0
16
X
DS-32
20
C
ST_REV
0
17
X
UNSIGNED16 2
N
TAG_DESC
0
18
X
X
OSTRING
32
S
STRATEGY
0
19
X
X
UNSIGNÈD16 2
S
ALERT_KEY
0
20
X
X
UNSIGNED8
1
S
TARGET_MODE
0
21
X
X
UNSIGNED8
1
S
MODE_BLK
0
22
X
DS-37
3
D
ALARM_SUM
0
23
X
DS-42
8
D
SOFTWARE_REVISION
0
24
X
OSTRING
16
C
HARDWARE_REVISION
0
25
X
OSTRING
16
C
DEVICE_MAN_ID
0
26
X
UNSIGNED16 2
C
DEVICE_ID
0
27
X
OSTRING
16
C
SERIALNUMBER
0
28
X
OSTRING
16
C
DIAGNOSIS
0
29
X
OSTRING
4
D
DIAGNOSIS_EXTENSION
0
30
X
OSTRING
6
D
DIAGNOSIS_MASK
0
31
X
OSTRING
4
C
DIAGNOSIS_MASK_EXTENSION
0
32
X
OSTRING
6
C
FACTORY_RESET
0
35
X
X
UNSIGNED16 2
S
DESCRIPTOR
0
36
X
X
OSTRING
32
S
DEVICE_MESSAGE
0
37
X
X
OSTRING
32
S
DEVICE_INSTAL_DATE
0
38
X
X
OSTRING
16
S
LOCAL_OP_ENA
0
39
X
X
UNSIGNED8
1
N
IDENT_NUMBER
0
40
X
X
UNSIGNED8
1
S
View_1 (diagnosis)
0
52
X
OSTRING
17
D