Alpha Technologies XM3-HP Series - Technical Manual User Manual
Page 23

23
017-882-B0-001 Rev. C2 (10/2013)
1.0
Introduction
Fig. 1-5, Front Panel, XM3-HP Power Supply
DOCSIS
®
Communications
Module
High Efficiency
Transformer Module
Intelligent Inverter
Module
1.3 Alpha XM3-HP CableUPS
®
Layout
The Intelligent CableUPS is comprised of the following:
Transformer module, which acts as a stand-alone line conditioner. The transformer module contains a
ferroresonant transformer, ferroresonant capacitor, line isolation relay, Power Distribution Board, EMC
Filter board and the optional AlphaDOC (PIM) board, Smart AlphaGuard (SAG) and Alpha APPS card.
Intelligent Inverter Module, which is required for standby operations and contains circuitry needed for
the three-to-five-stage temperature-compensated battery charger, DC to AC inverter, AC line detectors
and Smart Display.
Optional DOCSIS Communications Module (interfaces to Inverter Module) provides remote status
monitoring and communications.
1.3.1 Side Panel Connectors
AC Input Line Cord Connector
Optional Smart AlphaGuard Connector
Optional APPS Card
Output 1 Connector
Output 2 Connector
Fig. 1-6, Side Panel, XM3-HP Power Supply
1
2
3
4
5
1
2
3
4
5
1.0
Introduction, continued
The option cards require an Inverter Module installed in order to be functional.
NOTE: