Alpha Technologies Digital Midtron DM-3200 AT User Manual
Digital midtron, Quic
•
This test set is designed to take conductance
measurements exclusively on 6 and 12 Volt Lead/Acid
batteries while either on line (float service) or off line
•
Operating range:
Voltage: 5.5V – 15.0V DC
Amp Hour Range: approx. 5 Ah to 450 Ah,
•
Conductance: 0 – 3,200 Siemens
•
Test results: DC Voltage and Conductance (expressed in
Siemens) will be stored in internal memory after each test
until the next measurement. By depressing the “Review”
key, the last test result will be displayed for 15 seconds to
allow time to manually record the test information
•
Accuracy: +/- 2% across test range
•
Voltmeter resolution: +/- 20 mV DC
•
Calibration: Auto-calibration each test; no calibration
required
•
Power requirements: Unit is powered by the battery under
test; one replaceable 9V alkaline battery used to power
the display
•
Operating Temperature range: 0º C to +40º C, 95%
relative humidity, non-condensing
•
Storage Temperature Range: -29º C to + 70º C, 95%
relative humidity, non-condensing
•
Over Voltage Protection: Fused protected to 60 V DC
•
Fuse Specifications: 5mm x 20mm 1.25 Amp fuse
•
Reverse Polarity Protection: Diode protected
•
Test cables: Interchangeable interface. One standard
#C065 DuraProbe cable set and spare probe tips
provided with each tester – other interfaces available
from Alpha.
SPECIFICATIONS
BATTERY TESTING AND OPERATION
Automatic Battery Testing
The Digital Midtron Analyzer requires no setup or calibration.
Each unit is shipped with the DuraProbe cable pre-installed
and ready to test.
The Analyzer must have good contact with both the positive
and negative battery posts before it will begin to process the
test. The unit will then automatically begin upon the
establishment of a good connection.
(Continued on next page.)
®
Model: DM-3200 AT
Quic
Quic
Quic
Quic
Quick R
k R
k R
k R
k Ref
ef
ef
ef
efer
er
er
er
erence Guide
ence Guide
ence Guide
ence Guide
ence Guide
Digital Midtron
Alpha Technologies
3767 Alpha Way
Bellingham, WA
98226
Tel: 360-647-2360
Fax:360-671-4936
www.alpha.com
Alpha Technologies
1075 Satellite Blvd., Ste. 100
Suwanee, GA 30024
Tel: 678-387-3995
Fax:678-584-9259
www.alpha.com
®
Copyright © 2003
Alpha Technologies, Inc
P/N: DM-3200 AT
DEEP CYCLE SERIES
Siemens/Mhos
DCS-33
725
DCS-50SAE
850
DCS-75BT
1200
DCS-100L
1400
UPS—HIGH RATE SERIES (AGM)
UPS12-100
600
UPS12-140
950
UPS12-170
980
UPS12-200
1100
UPS12-270
1375
UPS12-310
1750
UPS12-370
1850
UPS12-475
2000
UPS6-620
4200
UPS-FLAME RETARDANT HIGH RATE SERIES
UPS12-100FR
600
UPS12-140FR
950
UPS12-170FR
980
UPS12-270FR
1375
UPS12-310FR
1750
UPS12-370FR
1850
UPS12-475FR
2000
UPS6-620FR
4200
MPS PRODUCTS (AGM)
MPS12-33
800
MPS12-50
980
MPS12-75
1200
MPS12-88
1300
MPS12-100
1400
TELECOMM—LONG DURATION SERIES (AGM)
TEL12-125
2000
TEL12-30
800
TEL12-30/SLC
800
TEL12-45
900
TEL12-45/SLC
900
TEL12-70
1125
TEL12-80
1325
TEL12-90
1590
TEL12-105F
1325
TEL6-180
ALPHACELL
85GXL
600
165GXL
1000
180GXL/190 Gold-HP
1100
160A
1300
210GXL/215 Gold-HP
1200
ALPHA BATTERIES - CONDUCTANCE REFERENCE NOS.