Extron Electronics VN-Matrix 250 User Guide User Manual

Page 31

background image

4.

At the

Please

select

an

option:

prompt, type the number of the parameter you wish

to change followed by :

z

0

a

or

10

b

— these options set the network link speed. When you choose either

option, you are offered a further choice:

1. auto_10_100_1000

— configures for auto speed negotiation up to 1 Gbps.

2. auto_10_100

— configures for auto speed negotiation up to 100 Mbps.

Enter

1

or

2

followed by at the prompt. The default setting is

1. auto_10_100_1000

.

NOTE: A Gigabit network is recommended for streaming media applications.

z

1

a

or

11

b

— these options determine whether the IP address of the unit will be static

or set by DHCP. When you choose either option, type

static

or

dhcp

followed by

. The default setting is

static

.

NOTES:

static

and

dhcp

are all lower case letters.

When

1

is set to

dhcp

, options

2

and

3

are not available. When

11

is set

to

dhcp

, options

12

14

are not available.

z

2

a

and

12

b

— these options set the local address of the network port. Standard

rules for IP addresses apply. The default values are

192.168.253.254

(control

network) and

192.168.254.254

(streaming network).

Do not use leading zeros. For example,

192.168.10.25

is valid;

192.168.010.025

is not valid.

NOTE: The control and streaming ports must be assigned to different subnets.

z

3

a

and

13

b

— these options set the network Subnet Mask. The default value is

255.255.255.0

. Standard rules for IP Addresses apply. Do not use leading zeros.

z

14

b

— this option sets the IP address for the default gateway. The default value is

192.168.254.1

.

This value is required for systems with multiple subnets. The Default Gateway must
be on the same subnet as the streaming port.
To clear a Gateway Address, select

14

and press with no value set.

z

Options

4

,

5

, and

15

are not available.

z

6

a

and

16

b

— these options set the Maximum Transmission Unit (MTU) Setting. The

default value is

1500

.

This value affects the system performance. Larger values may cause packets to
be fragmented (split) and smaller values may not make efficient use of the network
capacity.

z

7

a

and

17

b

— these options set the VLAN ID. The VLAN ID may be set on each of

the network ports. The default value is

0

.

NOTES:

a

Options

0

to

6

relate to the control network LAN 1. For full information about

Configuring the Control Port

, see page 32.

b

Options

10

to

16

relate to the streaming network LAN 2 (RJ‑45 or SFP).

VNM 250 • Low Level Device Configuration

25