beautypg.com

Alarms, Alarm types – Extron Electronics VN-Matrix 250 User Guide User Manual

Page 117

background image

Alarms

Alarm Types

The VNE 250 and VND 250 generate alarms in response to a range of error conditions.

Alarm Description Fault Description

Alarm Type

Encoder Alarms

No source

No source is connected at the input.

Critical,
Reporting

Bad Source Sync

An input source is connected but the signal
timing is not recognized. (Unable to input
source due to bad sync measurement.)

Critical,
Reporting

No SDI Source Lock
(

not applicable to

VNM 250

)

An SDI source is connected but the signal
timing is not recognized. (An SDI source is
present but the PLL lock failed.)

Critical,
Reporting

Unsupported
SDI Mode (

not

applicable to
VNM 250

)

The connected SDI mode is not supported.

Critical,
Reporting

Unsupported Mode

The connected source is not supported; a
user‑mode should be created.

Critical,
Reporting

Bad Source

A source is connected and syncs have been
detected but it is not possible to make active
pixel measurements.

Critical,
Reporting

Analog Phasing Error

The analog pixel clock auto‑phasing process
has failed.

Warning,
Reporting

Hardware Encoding
Error

The hardware is unable to encode the input
video.

Critical,
Reporting

Unsupported Audio
Source

The digital audio source has a bad or
unsupported clock rate.

Critical,
Reporting

Bad Audio Source

The audio source is not valid for the current
video source.

Warning,
Reporting

Data Rate Overload

The system is not able to process the
source at the current settings; increase the
compression. (The compressed data rate is
too high; increase the compression.)

Critical,
Reporting

Network Overload

The network is dropping too many packets.

Warning,
Reporting

Bad Reverse Audio

The reverse audio channel contains no data
or has a large number of dropouts

Warning,
Reporting

VNM 250 • Alarms