Output sub-menu, Output sub‑menu, The output sub‑menu allows you to – Extron Electronics VN-Matrix 250 User Guide User Manual
Page 112: Enable or disable decoding, Set power save to active or inactive, Scale the output resolution, Screen, press next to open the

Output Sub-menu
The
Output sub‑menu allows you to:
z
Enable or Disable decoding
z
Set Power save to Active or Inactive
z
Scale the output resolution
NEXT
Output
[Enable]
NEXT
NEXT
Power save
[Active]
Scale mode
[None]
Output
MENU
Select: Enable
Disable
Test
Select: Active
Disabled
Select: Unity
Display
User
Scale mode
[None]
Scale mode
[Display]
Scale mode
[User]
NEXT
NEXT
NEXT
Scale None
[Output Resolution]
Aspect Ratio
[Fill/Follow]
Set output res
[List of modes] [Refresh]
NEXT
NEXT
NEXT
Figure 88.
VND 250 Decoder Output Sub-menu
1.
In the main
Output
screen, press
Next to open the
Output
submenu.
2.
Use either rotary encoder to select
Enable (normal operation), Disable (stream
decoding is suspended), or
Test (stream decoding is suspended and replaced by a test
pattern).
NOTE: Changing the mode in this menu resets the Power save timeout.
3.
Press
Next to open the Power save screen.
4.
Use either rotary encoder to toggle between power save
Active or Disabled.
NOTE:
•
When power save is
Active, after 5 minutes with no active stream, the output
sync is dropped to allow a locally connected monitor to enter power save
mode.
•
When power save is
Disabled, sync is available at all times.
5.
Press
Next to open the Scale mode screen.
VNM 250 • Front Panel Menu Configuration