Reset Sub-menu

The

Reset sub‑menu allows you to reset many parameters to the factory defaults. It also

allows you to run the Sanitize process.

Reset

MENU

NEXT

Reset [Factory IP]

[Activate]

NEXT

NEXT

Are you sure?

[Yes]

System Reset

in progress

Figure 82.

VNE 250 Encoder Reset Sub-menu

1.

In the main

Reset screen, press Next to open the Reset Options screen.

2.

In the

Reset Options screen, use the right rotary encoder to select which type of reset

you want. You can choose

Factory IP or Sanitize:

Factory IP — restores the following parameters to the factory default:

z

IP address

z

Subnet mask

z

Gateway IP address

z

Controller IP address

z

Link speed set to auto

z

Static IP address

z

Controller port number

For factory default values see

figure 11

on page 24.

Sanitize — runs the sanitize process to overwrite volatile scaler memory (for the
on‑screen display), volatile Wavelet memory, and all non‑volatile memory. All these
memory locations are overwritten three times:

z

Firstly with a random pattern of zeroes and ones.

z

Secondly with binary zeroes.

z

Thirdly with binary ones.

3.

Use the left rotary encoder to toggle between

Activate or Cancel.

4.

Press

Next.

5.

If you selected

Activate in step 3, one of the reset processes runs. The screen shows

System Reset in Progress.

6.

When the reset is complete, press

Next to return to

Encode Config sub-menu

(see

page 93).

VNM 250 • Front Panel Menu Configuration