beautypg.com

Edid sub-menu, Edid sub‑menu – Extron Electronics VN-Matrix 250 User Guide User Manual

Page 103

background image

1.

In the main

Input screen, press Next to open the Input Source screen.

2.

In the

Input Source screen, use either rotary encoder to select the video source:

z

auto (selects HDMI whenever a digital source is detected)

z

HDMI (digital)

z

VGA (analog)

If the signal resolution and refresh rate are supported by VNE 250 (see

Supported

EDID Modes

on page 122), the LCD screen shows

Supported source: resolution

and

refresh rate of the signal. If the source signal is not supported, the screen shows

Unsupported Sce. If there is no source, the screen shows No source.

3.

Press

Next to open the Loop through screen.

4.

Use either rotary encoder to enable or disable the signal to the loop‑through monitor.

z

When

Enabled is selected, the source image or a splash screen is displayed on the

loop‑through monitor.

z

When

Disabled is selected, the loop‑through signal, including sync, is disabled.

NOTE: This setting applies to both VGA and HDMI loop‑through signals.

5.

Press

Next to open the Power save screen.

6.

Use either rotary encoder to enable or disable the power save feature.

z

When power save is

Enabled, the loop‑through signal is disabled when input

source syncs have been removed for 1 minute.

z

When power save is

Disabled, the loop‑through signal is always active.

NOTE:

Power save is only effective when Loop through is

Enabled.

This setting applies to both VGA and HDMI loop‑through signals.

EDID Sub-menu

The

EDID sub‑menu allows you to select the EDID that is provided to the source device.

EDID

MENU

NEXT

EDID Source

HDMI

NEXT

Select EDID Source: HDMI

VGA

EDID HDMI [Location]

[EDID name]

Select Location:

Different “EDID name” options
populate the list, depending on
the “Location” selected.

Transparent (Trans)

Stored (stored)

Fixed (fixed)

NEXT

Figure 80.

VNE 250 Encoder EDID Sub-menu

1.

In the main

EDID screen, press Next to open the EDID Source screen.

2.

In the

EDID Source screen, select the source type (HDMI or VGA).

3.

Press

Next to open the Location screen.

VNM 250 • Front Panel Menu Configuration