MS9500GL HD FrEND Plus
Chapter 12: Remote Control Protocols
Tcstopat
Sets the timecode stopat time
The Player will respond with:
OK or ERROR
Tcstart
Starts the timecode running (assumes the player is in Generate mode – refer to “The Timecode configuration
dialog” section of Chapter 6: Timecode)
The Player will respond with:
OK or ERROR
GPIO COMMANDS:
NOTE: This section applies to the MS9500GL only - the MS9500 does not accommodate GPIO.
When using the MS9500GL GPIO Interface module additional commands are available that enable the
MS9500GL to control or be controlled by an external device.
NOTE: Refer to Chapter 13: Using the GPIO Interface for more information.
Getinput
Verify the state of the four (4) GPIO Inputs.
The Player will respond with
inputstate 1(+ or -) 2(+ or -) 3(+ or -) 4(+ or -) where ‘+’ = ON ‘-‘ = OFF.
Getoutput
Verify the state of the four (4) GPIO Outputs.
The Player will respond with
outputstate 1(+ or -) 2(+ or -) 3(+ or -) 4(+ or -) where ‘+’ = ON ‘-‘ = OFF.
Setoutput
Change the state of the four (4) GPIO Outputs.
The Player will respond with
outputstate 1(+ or -) 2(+ or -) 3(+ or -) 4(+ or -) where ‘+’ = ON ‘-‘ = OFF.
System/Status Commands
Shutdown
Shut the Player system down.
The player doesn’t send a response to this command.