GIA 63 Message Advisories (Cont.)

Alerts Window Message

Comments

NAV1 RMT XFR – NAV1 remote
transfer key is stuck.

The remote NAV1 and/or NAV2 transfer switch is stuck in the enabled (or “pressed”)
state. Press the transfer switch again to cycle its operation. If the problem persists,
the G1000 system should be serviced.

NAV2 RMT XFR – NAV2 remote
transfer key is stuck.
G/S1 FAIL – G/S1 is inoperative.

A failure has been detected in glideslope receiver 1 and/or receiver 2. The G1000
system should be serviced.

G/S2 FAIL – G/S2 is inoperative.
G/S1 SERVICE – G/S1 needs service.
Return unit for repair.

A failure has been detected in glideslope receiver 1 and/or receiver 2. The receiver
may still be available. The G1000 system should be serviced when possible.

G/S2 SERVICE – G/S2 needs service.
Return unit for repair.

GEA 71 Message Advisories

Alerts Window Message

Comments

GEA1 CONFIG – GEA1 configuration
error. Config service req’d.

The GEA 71 configuration settings do not match those of backup configuration
memory. The G1000 system should be serviced.

MANIFEST – GEA1 software
mismatch. Communication halted.

The GEA 71 has incorrect software installed. The G1000 system should be serviced.

BACKUP PATH – EIS using backup
data path.

The GEA 71 is using a backup communication path. The G1000 system should be
serviced when possible.

GTX 33 Message Advisories

Alerts Window Message

Comments

XPDR1 CONFIG – XPDR1 config error.
Config service req’d.

The transponder configuration settings do not match those of backup configuration
memory. The G1000 system should be serviced.

MANIFEST – GTX1 software mismatch.
Communication halted.

The transponder has incorrect software installed. The G1000 system should be
serviced.

BACKUP PATH – XPDR1 using backup
data path.

The #1 transponder is using a backup communications path. The G1000 system
should be serviced when possible.