APPENDIX A

MFD & PFD Message Advisories

Message

Comments

DATA LOST – Pilot stored data was
lost. Recheck settings.

The pilot profile data was lost. System reverts to default pilot profile and settings.
The pilot may reconfigure the MFD & PFD with preferred settings, if desired.

XTALK ERROR – A flight display
crosstalk error has occurred.

The MFD and PFD are not communicating with each other. The G1000 system should
be serviced.

PFD1 SERVICE – PFD1 needs service.
Return unit for repair.

The PFD and/or MFD self-test has detected a problem. The G1000 system should be
serviced.

PFD2 SERVICE – PFD2 needs service.
Return unit for repair.
MFD1 SERVICE – MFD1 needs
service. Return unit for repair.
PFD1 CONFIG – PFD1 configuration
error. Config service req’d.

The PFD and/or MFD configuration settings do not match backup configuration
memory. The G1000 system should be serviced.

PFD2 CONFIG – PFD2 configuration
error. Config service req’d.
MFD1 CONFIG – MFD1 configuration
error. Config service req’d.
SW MISMATCH – GDU software
mismatch. Xtalk is off.

The MFD and PFD have different software versions installed. The G1000 system
should be serviced.

MANIFEST – PFD1 software mismatch.
Communication halted.

The PFD and/or MFD has incorrect software installed. The G1000 system should be
serviced.

MANIFEST – MFD1 software
mismatch. Communication halted.
PFD1 COOLING – PFD1 has poor
cooling. Reducing power usage.

The PFD and/or MFD is overheating and is reducing power consumption by dimming
the display. If problem persists, the G1000 system should be serviced.

PFD2 COOLING – PFD2 has poor
cooling. Reducing power usage.
MFD1 COOLING – MFD1 has poor
cooling. Reducing power usage.
PFD1 “KEY” KEYSTK – Key is stuck.

A key is stuck on the PFD and/or MFD bezel. Attempt to free the stuck key by press-
ing it several times. The G1000 system should be serviced if the problem persists.

PFD2 “KEY” KEYSTK – Key is stuck.
MFD1 “KEY” KEYSTK – Key is stuck.
CNFG MODULE – PFD1 configuration
module is inoperative.

The PFD configuration module backup memory has failed. The G1000 system should
be serviced.