NUMBER OF MOTOR
316
Number of motor poles
2, 4, 6, 8, 10, 12, 14,
2
4
9-29
POLES
16
MOTOR RATED CAPACITY
317
Motor rated capacity
0.1 - 999.9
0.1kW
*
9-29
MOTOR TYPE
318
Motor type
0: High efficiency
-
0
9-29
motor
1: Standard motor
2: Other**
MOTOR RATED VOLTAGE
319**
Rated voltage for 400V inverter
90 - 600
5V
400
9-29
Rated voltage for 200V inverter
90 - 600
5V
200
9-29
MOTOR RATED
320**
Rated frequency
0 - 400
2 Hz
60
9-29
FREQUENCY
MOTOR RATED RPM
321**
Rated RPM
0 - 9999
1 RPM
1710
9-29
AUTO-TUNING ENABLE
322**
Auto-tuning ***
0: Auto-tuning
-
0
9-29
disabled
1: Auto-tuning
enabled
LOAD MOMENT OF
323
Load moment of inertia
0: Small
-
1
9-29
INERTIA
1: Medium
2: Large
3: Very large
8 - 32
PARAMETER
DESCRIPTION
LIQUID CRYSTAL DISPLAY
ADJUSTMENT
RANGE
ITEM
NO.
PAGE
NO.
DISPLAY
RESOLUTION
FACTORY
SETTING
GROUP:MOTOR PARAMETERS
*Item 317 factory setting depends on inverter rating (1 HP = .746kW)
**Items 319 - 322 are available only when Item 318 Adjustment Range option 2 is selected.
***Inverters sized 150 HP and larger cannot be auto-tuned.