Toshiba, Group:terminal selection parameters – Toshiba Adjustable Speed Drive H3 User Manual
Page 40
TOSHIBA
INPUT TERMINAL
43
Input terminal selection
0: Standard terminal
-
0
9-7
SELECTION
functions
1: custom terminal
functions *
"R" INPUT TERMINAL
44*
assign function to "R" terminal
0 - 54
-
0
9-7
FUNCTION
(default function is reverse run)
5-1
"S1" INPUT TERMINAL
45*
assign function to"S1" terminal
0 - 54
-
1
9-7
FUNCTION
(default function is preset speed)
5-1
"S2" INPUT TERMINAL
46*
assign function to "S2" terminal
0 - 54
-
2
9-7
FUNCTION
(default function is preset speed)
5-1
"S3" INPUT TERMINAL
47*
assign function to "S3" terminal
0 - 54
-
3
9-7
FUNCTION
(default function is preset speed)
5-1
"S4" INPUT TERMINAL
48*
assign function to "S4" terminal
0 - 54
-
4
9-7
FUNCTION
(default function is preset speed)
5-1
"F" INPUT TERMINAL
49*
assign function to "F" terminal
0 - 54
-
5
9-7
FUNCTION
(default function is forward run)
5-1
"RES" INPUT TERMINAL
50*
assign function to "RES" terminal
0 - 54
-
6
9-8
FUNCTION
(default function is fault reset)
5-1
"ST" INPUT TERMINAL
51*
assign function to "ST" terminal
0 - 54
-
7
9-8
FUNCTION
(default function is drive enable)
5-1
"S5" INPUT TERMINAL
52*
assign function to "S5" terminal
0 - 54
-
8
9-8
FUNCTION
(available on option board)
"S6" INPUT TERMINAL
53*
assign function to "S6" terminal
0 - 54
-
9
9-8
FUNCTION
(available on option board)
"S7" INPUT TERMINAL
54*
assign function to "S7" terminal
0 - 54
-
10
9-8
FUNCTION
(available on option board)
POTENTIAL TERMINAL
55*
pick function that is always active
0 - 42
-
33
9-8
FUNCTION
(no physical connection)
R, S1-S7 TERMINAL
56
"R" and "S1"-"S7" terminals'
1 - 100
1
6
9-10
RESPONSE TIME
response time
5-1
"F" INPUT TERMINAL
57
"F" terminal response
1 - 100
1
6
9-10
RESPONSE TIME
time selection
5-1
"RES" INPUT TERMINAL
58
"RES" terminal response
1 - 100
1
6
9-10
RESPONSE TIME
time selection
5-1
"ST" INPUT TERMINAL
59
"ST" terminal response
1 - 100
1
6
9-10
RESPONSE TIME
time selection
5-1
"RCH" CONTACTS
60
assign function to "RCH"
0 - 63
1
6
9-10
FUNCTION
output contact
5-1
"RCH" CONTACTS
61
"RCH" output contact delay time
1 - 100
1
1
9-10
DELAY TIME
5-1
"RCH" CONTACTS
62
"RCH" output contact hold time
1 - 100
1
1
9-10
HOLD TIME
5-1
8 - 5
GROUP:TERMINAL SELECTION PARAMETERS
PARAMETER
DESCRIPTION
LIQUID CRYSTAL DISPLAY
ADJUSTMENT
RANGE
ITEM
NO.
PAGE
NO.
DISPLAY
RESOLUTION
FACTORY
SETTING
Table continued on next page
*Items 44 - 55 are available only when Item 43 Adjustment Range option 1 is selected.