beautypg.com

Toshiba Adjustable Speed Drive H3 User Manual

Page 17

background image

TOSHIBA

SECTION 4: Wiring

Standard Connection Diagrams

4 - 1

TOSVERT-130H3

STANDARD CONNECTION

MODEL 2035 TO 2330
MODEL 4055 TO 4330

DBR

PROGRAMMABLE
OUTPUT CONTACTS
250V, 2A MAX

PROGRAMMABLE
OUTPUT CONTACTS
250V, 2A MAX

PROGRAMMABLE
SIGNAL INPUT

PROGRAMMABLE
ANALOG INPUT

DIGITAL
OPERATION PANEL

L3(T)

F

RES

R

ST

S1

S2

L2(S)

(see note 3 below) S4

FLA

CC

FLB

R/CH-C

LOW-A

P24

FP

FM

AM

CC

AM

FM

M

L1(R)

MCCB

PA

PB

+

+

AUTO

REF.

AUTO

REF.

-

-

IV

RX

CC

RR

PP

S3

T3(W)

T2(V)

T1(U)

R/CH-A

LOW-C

50mA MAX

PULSE OUTPUT

+

+

PROGRAMMABLE
SIGNAL OUTPUT
0-1mA or 4-20mA

M

FLC

GND(E)

INPUT POWER SUPPLY
(see notes 1 and 2 below)

Potentiometer

NOTES:

1.)

For drive models 2035 through 2330 use input power supply of 200VAC, 50Hz or
200-230VAC, 60Hz.

2.)

For drive models 4055 through 4330 use input power supply of 380VAC, 50Hz or
400-460VAC, 60Hz.

3.)

As an example, the "S4" terminal is shown above as an EMERGENCY OFF input. See
Section 8 for information on how to program the drive for this and other functions.

Specifications

Precautions

Wiring

Jumpers

Panel

Keypad

Parameters

Programming

Service

Dimensions

Index

Inspection