REGENERATION POWER

155

allows drive to use regen

0: Off

-

0

9-17

RIDE-THROUGH

for control power

1: On *

REGENERATION RIDE

-

156*

maximum allowable

0.0 - 25

0.1 sec

2.0

9-17

THROUGH TIME

ride-through time

AUTO-RESTART (MOTOR

157

"catch" a spinning motor

0: Off

-

0

9-17

SPEED SEARCH)

(forward or reverse)

1: After momentary

power failure

(ride-through)
2: After "ST" is

shorted to "CC"

3: Both 1 and 2

ELECTRONIC THERMAL

158

sets drive's overload to

10-100% or amps

1%/A

100

9-18

PROTECT LVL 1

protect motor

OVERLOAD REDUCTION

159

frequency at which drive's motor

0 - 30

0.1/0.01 Hz

30.0

9-18

START FREQ

overload becomes speed sensitive

MOTOR 150% OVERLOAD

160

sets motor overload time

10 - 2400

10 sec

600

9-18

TIME LIMIT

OVERLOAD SELECTION

161

OL selection

0: Standard

-

0

9-18

1: Soft stall on
2: Motor OL trip off
3: Soft stall on,

Motor OL trip off

STALL PROTECTION

162

Stall protection #1

0: On **

-

0

9-18

ENABLE

1: Off

STALL PROTECTION

163**

sets current limit

10 - 215%/A

1 %/A

120

9-18

CURRENT LEVEL

UNDERVOLTAGE TRIP

164

Undervoltage detection can

0: Trip disabled

-

0

9-18

SELECTION

cause a warning or a trip

1: Trip enabled

UNDERVOLTAGE DETECT

165

Undervoltage detection time

0 - 10

0.01 sec

0.03

9-18

TIME

LOW CURRENT DETECT

166

Low current detection can

0: Trip disabled

-

0

9-18

SELECTION

cause a warning or a trip

1: Trip enabled

LOW CURRENT DETECT

167

Low current detection level

0 - 100% or amps

1%/A

0

9-19

LEVEL

LOW CURRENT

168

Low current detection time

0 - 255

1 sec

0

9-19

DETECTION TIME

OUTPUT SHORT-CIRCUIT

169

Output short-circuit detection

0: Standard

-

0

9-19

DETECTION SELECT

selection (OCL)

1: Less sensitive

short-circuit checki

2: Short-circuit check

at power up only

3: Combination of

1 and 2 above

8 - 14

GROUP:PROTECTION PARAMETERS

(cont'd)

PARAMETER

DESCRIPTION

LIQUID CRYSTAL DISPLAY

ADJUSTMENT

RANGE

ITEM

NO.

PAGE

NO.

DISPLAY

RESOLUTION

FACTORY

SETTING

Table continued on next page

*Item 156 is available only when Item 155 Adjustment Range option 1 is selected.