Toshiba, Group:communication setting parameters – Toshiba Adjustable Speed Drive H3 User Manual
Page 59
TOSHIBA
8 - 24
LIQUID CRYSTAL DISPLAY
ADJUSTMENT
RANGE
ITEM
NO.
PAGE
NO.
DISPLAY
RESOLUTION
FACTORY
SETTING
PARAMETER
DESCRIPTION
GROUP:COMMUNICATION SETTING PARAMETERS
Cycle power after changing any parameter in
GROUP: COMMUNICATION SETTING PARAMETERS
.
Table continued on next page
*Items 265 - 266 are available only when Item 264 Adjustment Range option 1 is selected.
**Item 267 is available only when Item 264 Adjustment Range option 2 or 3 is selected.
RS232 BAUD RATE
260
set RS232 baud rate
0: 2400 baud
-
2
9-22
1: 4800 baud
2: 9600 baud
NUMBER OF DATA BITS
261
Number of data bits
0: 7 bits
-
0
9-22
1: 8 bits
PARITY SETTING
262
Parity
0: Even parity
-
0
9-22
1: Odd parity
INVERTER ID NUMBER
263
Inverter number
0 - 255
-
0
9-22
COMMUNICATION
264
Communication selection
0: Off
-
0
9-23
SELECTION
1: RS485 board*
2: Tosline-F10,
DN board,
MB+ board,
RIO board**
3: Tosline-S20 **
4: 12-bit binary input
(option board)
5: BCD board
(0.1 Hz units)
6: BCD board
(1 Hz units)
MASTER/SLAVE
265*
Master/follower selection
0: Follower
-
0
9-23
SELECTION
1: Master (follower
follows master
freq. command)
2: Master (output
frequency)
RS485 BAUD RATE
266*
RS485 baud rate
0: Normal mode
-
0
9-23
1: High speed mode
TOSLINE-F10/S20
267**
TOSLINE-F10/TOSLINE-S20
0: Off
-
0
9-23
COMMAND INPUT
command input
1: Frequency
command
2: Command input
3: Frequency
command,
command input
Specifications
Precautions
Wiring
Jumpers
Panel
Keypad
Parameters
Programming
Service
Dimensions
Index
Inspection