Toshiba, Group:frequency setting parameters – Toshiba Adjustable Speed Drive H3 User Manual
Page 43
TOSHIBA
8 - 8
GROUP:FREQUENCY SETTING PARAMETERS
PARAMETER
DESCRIPTION
LIQUID CRYSTAL DISPLAY
ADJUSTMENT
RANGE
ITEM
NO.
PAGE
NO.
DISPLAY
RESOLUTION
FACTORY
SETTING
Table continued on next page
*Items 84 - 87 are available only when Item 83 Adjustment Range option 1 is selected.
**Items 89 - 92 are available only when Item 88 Adjustment Range option 1 is selected.
***Items 94 - 97 are available only when Item 93 Adjustment Range option 1 is selected.
FREQUENCY PRIORITY
80
Assign priority to frequency
1:RR terminal
-
1
9-13
SELECTION #1
reference sources
2:IV terminal
3:RX terminal
4:PG input
5:Binary input or MOP
FREQUENCY PRIORITY
81
Assign second priority
1:RR terminal
2
9-13
SELECTION #2
frequency reference source
2:IV terminal
3:RX terminal
4:PG input
5:Binary input or MOP
ANALOG INPUT FILTER
82
Analog input filter
0 - 3
-
0
9-14
RR TERMINAL STANDARD
83
RR input selection
0: Standard
-
0
9-14
OR ADJUSTABLE
1: Adjustable *
5-1
RR REFERENCE SETTING
84*
RR reference point #1
0 - 100%
1%
0
9-14
POINT #1
of terminal max (10V)
RR REF POINT #1
85*
Output frequency desired
0 - Max. Out. Freq.
0.1/0.01 Hz
0.0
9-14
FREQUENCY
with input entered in Item 84
RR REFERENCE SETTING
86*
RR reference point #2
0 - 100%
1%
100
9-14
POINT #2
of terminal max (10V)
RR REF POINT #2
87*
Output frequency desired
0 - Max.Out. Freq.
0.1/0.01 Hz
80.0
9-14
FREQUENCY
with input entered in Item 86
IV TERMINAL STANDARD
88
IV input selection
0: Standard
-
0
9-14
OR ADJUSTABLE
1: Adjustable **
5-1
IV REFERENCE SETTING
89**
IV reference point #1
0 - 100%
1%
20
9-14
POINT #1
of terminal maximum
IV REF POINT #1
90**
Output frequency desired
0 - Max. Out. Freq.
0.1/0.01 Hz
0.0
9-14
FREQUENCY
with input entered inItem 89
IV REFERENCE SETTING
91**
IV reference point #2
0 - 100%
1%
100
9-14
POINT #2
of terminal maximum
IV REF POINT #2
92**
Output frequency desired
0 - Max. Out. Freq.
0.1/0.01 Hz
80.0
9-14
FREQUENCY
with input entered in Item 91
RX TERMINAL STANDARD
93
RX input selection
0: Standard
-
0
9-14
OR ADJUSTABLE
1: Adjustable ***
5-1
RX REFERENCE SETTING
94***
RX reference point #1
-100 - 100%
1%
0
9-14
POINT #1
of terminal maximum
RX REF POINT #1
95***
Output Hz desired with input
-Max. Out. Freq. to
0.1/0.01 Hz
0.0
9-14
FREQUENCY
entered in Item 94
Max. Out. Freq.
RX REFERENCE SETTING
96***
RX reference point #2
-100 - 100%
1%
100
9-14
POINT #2
of terminal maximum
RX REF POINT #2
97***
Output Hz desired with input
-Max. Out. Freq. to
0.1/0.01 Hz
80.0
9-14
FREQUENCY
entered in Item 96
Max. Out. Freq.
Specifications
Precautions
Wiring
Jumpers
Panel
Keypad
Parameters
Programming
Service
Dimensions
Index
Inspection