4 - 3
Selection of Main Circuit Wiring Equipment and Standard Cable Sizes
3-core shield cable
#18
(speed reference)
2-core shield cable
#20
Specifications
Precautions
Wiring
Jumpers
Panel
Keypad
Parameters
Programming
Service
Dimensions
Index
Inspection
* Molded case
Ampacity
Drive
circuit breaker (FLA x 1.25)
** Typical cable size (AWG)
(MCCB)
Amp
Main power Input and Output Frequency command input,
Other
Model Number
rating
(A)
and
Lug frequency meter, ammeter
signal
(A)
motor load
Wire Capacity
circuits
H3-2035
20
13.3
#14
24-12 / 24-12
H3-2055
30
21.3
#14
24-12 / 24-12
H3-2080
50
30.4
#10
24-8 / 24-8
H3-2110
70
41.3
#8
18-2 / 18-2
H3-2160
90
57.5
#6
18-2 / 18-2
H3-2220
100
75.0
#4
18-2 / 18-2
H3-2270
125
93.8
#3
18-2 / 14-2/0
H3-2330
150
111.3
#2
6-250 / 6-250
H3-4055
15
9.5
#14
24-12 / 24-12
H3-4080
30
13.8
#14
24-8 / 24-8
H3-4110
30
18.8
#14
24-8 / 24-8
H3-4160
40
27.5
#10
18-2 / 14-2
H3-4220
50
35
#8
18-2 / 14-2
H3-4270
70
42.5
#8
18-2 / 14-2
H3-4330
90
50
#6
18-2 / 14-2
H3-4400
100
70
#4
18-2 / 14-2
H3-4500
100
81.3
#3
18-2 / 14-2
H3-4600
125
102.5
#2
6-250 / 6-250
H3-4750
175
130.0
#1
6-250 / 6-250
H3-410K
200
155
#2/0
6-250 / 6-250
H3-412K
225
195
#4/0
6-250 / 6-250
H3-415K
300
225
*** 2 (#2/0)
6-250 / 6-250
H3-420K
350
300
*** 2 (#2/0)
6-250 / 6-250
H3-425K
400
375
*** 2 (#4/0)
6-250 / 6-250
H3-430K
600
450
*** 2 (#250)
6-250 / 6-250
See page 4-4 for notes.