beautypg.com

Toshiba, Group:fundamental parameters #2 – Toshiba Adjustable Speed Drive H3 User Manual

Page 37

background image

TOSHIBA

BASE FREQUENCY #2

15

Base frequency #2

25 - 400 Hz

0.01/0.1 Hz

60.0

9-5

MAXIMUM OUTPUT

16

Maximum voltage #2 for 230V

0 - 255V

1V

230V

9-5

VOLTAGE #2

Maximum voltage #2 for 460V

0 - 510V

1V

460V

9-5

VOLTAGE BOOST #2

17 *

30 HP and less

0 - 30%

0.1%

3%

9-5

40 HP and greater

1%

ELECTRONIC THERMAL

18

Electronic thermal protection

10-100% or amps

1%/A

100

9-5

PROTECT LVL #2

level #2

STALL PROTECTION

19

turn stall #2 on/off

0: On **

-

0

9-5

SELECTION #2

1: Off

STALL PROTECTION

20**

adjust stall current level #2

10-215% or amps

1%/A

120%

9-5

LEVEL #2

ACCELERATION TIME #2

21

60 HP and less

0.1-6000/0.01-600.0

0.1s/0.01s

10 sec

9-5

75 HP and greater

60 sec

DECELERATION TIME #2

22

60 HP and less

0.1-6000/0.01-600.0

0.1s/0.01s

10 sec

9-5

75 HP and greater

60 sec

ACC/DEC PATTERN #2

23

Acc/Dec pattern #2

0: Linear

-

0

9-5

SELECTION

1: Self-adjusting
2: S-Pattern
3: Overspeed Pattern

ACC/DEC #1/#2 SWITCH

24

Hz at which to switch from

0 - Max. Output Freq. 0.1/0.01 Hz

0.0

9-5

FREQUENCY

ACC1/DEC1 to ACC2/DEC2

(Item 1)

8 - 2

GROUP:FUNDAMENTAL PARAMETERS #2

PARAMETER

DESCRIPTION

LIQUID CRYSTAL DISPLAY

ADJUSTMENT

RANGE

ITEM

NO.

PAGE

NO.

DISPLAY

RESOLUTION

FACTORY

SETTING

*Item 17 is available only when Item 8,

VOLTS PER HERTZ PATTERN

Adjustment Range option 1 or 2

is selected.
**Item 20 is available only when Item 19 Adjustment Range option 0 is selected.

Specifications

Precautions

Wiring

Jumpers

Panel

Keypad

Parameters

Programming

Service

Dimensions

Index