Events and levels, Event log – TANDBERG D14049.04 User Manual

Page 49

background image

49

D14049.04
JULY 2008

Grey Headline (continued)

Events and Levels

Event

Description

Level

Admin Session Finish

An administrator has logged off the system.

1

Admin Session Login Failure

An unsuccessful attempt has been made to log in as an administrator. This could be because an incorrect username or password (or both) was entered.

1

Admin Session Start

An administrator has logged onto the system.

1

Application Failed

The VCS application is out of service due to an unexpected failure.

1

Application Start

The VCS has started. Further detail may be provided in the

Detail

event parameter.

1

Application Warning

The VCS application is still running but has experienced a recoverable problem. Further detail may be provided in the

Detail

event parameter.

1

Beginning System Backup

A system backup has started.

1

Beginning System Restore

A system restore has started.

1

Call Answer Attempted

An attempt to answer a call has been made.

1

Call Attempted

A call has been attempted.

1

Call Connected

A call has been connected.

1

Call Diverted

A call has been diverted.

1

Call Disconnected

A call has been disconnected.

1

Call Rejected

A call has been rejected. The

Reason

event parameter contains a textual representation of the H.225 additional cause code.

1

Completed System Backup

A system backup has completed.

1

Completed System restore

A system restore has completed.

1

Decode Error

A syntax error was encountered when decoding a SIP or H.323 message.

1

Eventlog Cleared

An operator cleared the event log.

1

External Server

Communication Failure

Communication with an external server failed unexpectedly. The

Detail

event parameter should differentiate between ‘no response’ and ‘request

rejected’. Servers concerned are:

DNS

LDAP servers

Neighbor Gatekeeper

NTP servers

Peers

1

Hardware Failure

There is an issue with the VCS hardware. If the problem persists, contact your TANDBERG support representative.

1

License Limit Reached

Licensing limits for a given feature have been reached. The

Detail

event parameter specifies the facility/limits concerned. Possible values for the detail

field are:

Non Traversal Call Limit Reached

Traversal Call Limit Reached

1

TANDBERG

VIDEO COMMUNICATIONS SERVER

ADMINISTRATOR GUIDE

Introduction

Getting Started

Overview and

Status

System

Configuration

VCS

Configuration

Zones and

Neighbors

Call

Processing

Bandwidth

Control

Firewall

Traversal

Appendices

Applications

Maintenance

Event Log