beautypg.com

Maxim Integrated DS21Q55 User Manual

Page 55

background image

Product Preview

DS21Q55

55 of 248

012103

Please contact

[email protected]

or search

http://www.maxim-ic.com

for updated

information.


Register Name:

E1TCR2

Register Description:

E1 Transmit Control Register 2

Register Address:

36h


Bit #

7

6

5

4

3

2

1

0

Name

Sa8S

Sa7S

Sa6S

Sa5S

Sa4S

AEBE

AAIS

ARA

Default

0

0

0

0

0

0

0

0



Bit 0/Automatic Remote Alarm Generation (ARA).

0 = disabled
1 = enabled


Bit 1/Automatic AIS Generation (AAIS).

0 = disabled
1 = enabled


Bit 2/Automatic E-Bit Enable (AEBE).

0 = E-bits not automatically set in the transmit direction
1 = E-bits automatically set in the transmit direction


Bit 3/Sa4-Bit Select (Sa4S).
Set to one to source the Sa4 bit from the TLINK pin; set to zero to not source the Sa4 bit. See
Functional Timing Diagrams
for details.

Bit 4/Sa5-Bit Select (Sa5S).
Set to one to source the Sa5 bit from the TLINK pin; set to zero to not source the Sa5 bit. See
Functional Timing Diagrams for details.

Bit 5/Sa6-Bit Select (Sa6S).
Set to one to source the Sa6 bit from the TLINK pin; set to zero to not so urce the Sa6 bit. See
Functional Timing Diagrams for details.

Bit 6/Sa7-Bit Select (Sa7S).
Set to one to source the Sa7 bit from the TLINK pin; set to zero to not source the Sa7 bit. See
Functional Timing Diagrams for details.

Bit 7/Sa8-Bit Select (Sa8S).
Set to one to source the Sa8 bit from the TLINK pin; set to zero to not source the Sa8 bit. See
Functional Timing Diagrams for details.